Jet Fuel Storage Tank Replacement at Engine Test Cell Facility

The intent of this project is to replace the underground jet fuel storage tank at the B-175 Jet Engine Test Cell with a new, double-wall, aboveground storage tank. Specific methods shall be as described below. Work Requirements: a. Construction: 1. Install new concrete pad, tank footings, and containment curb in accord…

Source ID: 798ccd8a16544627b2ed796aae8216ac

Estimated value

$2.6 Million

As published by the source; may be updated by the buyer.

Scope overview

The intent of this project is to replace the underground jet fuel storage tank at the B-175 Jet Engine Test Cell with a new, double-wall, aboveground storage tank. Specific methods shall be as described below. Work Requirements: a. Construction: 1. Install new concrete pad, tank footings, and containment curb in accordance with the drawing requirements including piping and conduit penetrations. 2.

Install a new 20,000 gallon factory fabricated, double wall, protected, above-ground jet fuel storage tank including platform and stairway as indicated on the drawing. 3. Install new concrete fuel pipe trench with traffic rated grating as indicated on the drawing. 4. Install new electrical pull boxes, concrete ductbank, and conduits as indicated on the drawing. 5.

Install new two new fuel pumps in accordance with the pump schedule. 6. Relocate indicated devices and piping including new cathodic protection for underground piping. 7. Relocate existing emergency stop panel as indicated and add a new readout for the automatic tank gauge system. 8. Install new stainless steel piping and valves as indicated to re-establish all connections with the new above-ground tank. 9.

Install bollards all the way around the new tank and pad area as indicated on the drawing. 10. Install new light post where indicated on the drawing, including switch near the stairwell. 11. Install new fire hydrant where indicated on the drawing. 12. Install a new eyewash station as indicated. 13. Perform all requisite equipment testing and verifications in accordance with specification requirements. b.

Demolition: 1. Demolish and remove all concrete as indicated above the underground tank to provide access for excavation of the tank. 2. Remove existing devices and piping to be relocated as indicated on the drawing. 3. Remove existing emergency stop panel and associated conduit to be relocated as indicated on the drawing. 4.

Remove existing cathodic protection test wells and associated cabling and anodes where indicated. 5. Remove existing fiberglass transition sump and concrete collar as indicated. 6. Remove the existing fuel pumps, associated devices, and electrical boxes and conduits as indicated. 7. Excavate and completely remove the 20,000 gallon underground jet fuel storage tank.

This tank removal must be completed (out of the ground) by December 31st 2025. Liquidated damages may be assessed as detailed in Section 1.7 for this activity. 8. Remove the concrete base beneath the existing underground tank. 9. Perform all requisite clean-up and testing associated with the removal in accordance with all of the federal, state, and local environmental requirements. 10.

Remove existing fire hydrant and associated piping as indicated. 10. Remove existing valve, valve box, pedestal type hose bib, and associated piping as indicated. 11. Remove existing bollards where indicated. 12. Remove existing concrete ductbank and conduits back to the building as indicated. 13. Remove existing double wall fuel supply and return pipes back to the building as indicated.

Statusawarded
CategoryOther
CountryUnited States
Publish dateFeb 3, 2026
Submission deadlineFeb 16, 2026
Estimated value$2.6 Million
Notice typeaward_notice
Sourceus-sam-opportunities
BuyerDEPT OF DEFENSE.DEPT OF THE NAVY.NAVFAC.NAVFAC PACIFIC CMD.NAVFAC SOUTHWEST SW.NAVFACSYSCOM SOUTHWEST
Buyer websitehttps://sam.gov/
CityLemoore

Buyer & contacts

Public read-only access
Contact fields are visible publicly. Use the workspace for exports, buyer tracking, and alerts.
Open workspace
Contact nameNathalie Zielinski
Emailnathalie.m.zielinski.civ@us.navy.mil
Phone5599983892
OrganizationDEPT OF DEFENSE.DEPT OF THE NAVY.NAVFAC.NAVFAC PACIFIC CMD.NAVFAC SOUTHWEST SW.NAVFACSYSCOM SOUTHWEST

Tags & Signals

jet fuel storage tankaboveground tank installationfuel system replacementengine test celltank demolitionfuel infrastructuredouble-wall tankaviation fuel system
Unlock actions

Keep reading for free. Pay only when you need workspace actions.

This record stays public. Upgrade only when you want alerts, exports, OCR packs, and autopilot workflows inside the private workspace.

Disclaimer: IndexBox Tenders does not issue, announce, or publish this tender. This information is aggregated from publicly available sources and is provided for informational purposes only. IndexBox Tenders is not affiliated with, endorsed by, or acting on behalf of the tender issuer. Users should verify all information directly with the official tender source before making any decisions or taking any action.