Watermain Pipeline Construction Project in Hanmer Springs

The project is located in Hanmer Springs, North Canterbury. The proposed new watermain will run from Conical Hill Road Intersection, and along Chalet Crescent as far as 85 Chalet Crescent, Hanmer, North Canterbury Stage 1 of the main contract of works: ? The works involved in the construction of a proposed pipeline con…

Source ID: NZ-GETS-23995436

Estimated value

NZ$413,475

As published by the source; may be updated by the buyer.

Scope overview

The project is located in Hanmer Springs, North Canterbury. The proposed new watermain will run from Conical Hill Road Intersection, and along Chalet Crescent as far as 85 Chalet Crescent, Hanmer, North Canterbury Stage 1 of the main contract of works: ?

The works involved in the construction of a proposed pipeline consists of approximately 600 metres of DN180 PE 100 PN12.5 watermain and approximately 580m of DN63 PE80B PN12.5 Rider-main, in a common trench with the DN180. ? Complete the road crossing at the junction with Conical Hill Rd. ? An additional 350mtrs of DN63 PE80B PN12.5 watermain to run in the footpath as per the tender drawings (Appendix B) ?

The project will also consist of valves, fire hydrants, gate valves, connections to the DN180 and connections to all laterals in conjunction with the new mains. ? The Contractor is to supply and install all valves, fittings and to perform all pipe welding. ?

Hurunui District Council will supply the DN180 PE100 PN12.5, but the contractor will have to arrange for collection and transport of the pipe from our HDC Hanmer Utility Shed on Jacks Pass Rd. ? The Contractor will also be responsible for all health, safety, and environmental aspects of the project. The Contractor will also be responsible for the reinstatement of all surfaces.

Separable Portion Stage 2 The Separable Portion is solely dependent on the available budget and is to be awarded at the Engineers discretion. The works consists of the following. ? Continuation of the approx. 167 meters of DN180 PE 100 PN12.5 and approximately 167 meters of DN63 PE80B PN12.5 Rider-main, in a common trench with the DN180 to complete the Loop at Chalet crescent. ?

Complete the road crossing at the junction with Acheron Hills drive. ? Continuation of DN63 PE80B PN12.5 watermain in the footpath to the valve tie in point at Acheron Hills drive. ? The project will also consist of valves, fire hydrants, gate valves, connections to the DN180 and connections to all laterals in conjunction with the new mains. ?

The Contractor is to supply and install all valves, fittings and to perform all pipe welding. ? Hurunui District Council will supply the DN180 PE100 PN12.5, but the contractor will have to arrange for collection and transport of the pipe from our HDC Hanmer Utility Shed on Jacks Pass Rd. ? The Contractor will also be responsible for all health, safety, and environmental aspects of the project.

The Contractor will also be responsible for the reinstatement

Statusawarded
CategoryConstruction & Infrastructure
CountryNew Zealand
Publish dateFeb 18, 2021
Submission deadlineMar 26, 2021
Estimated valueNZ$413,475
Notice typeaward_notice
Sourcenz-gets-awards
BuyerHurunui District Council
City

Buyer & contacts

OrganizationHurunui District Council

Tags & Signals

watermain constructionpipeline installationHanmer SpringsChalet CrescentPE piperoad crossingvalve installationhydrant installation

Need alerts, export, or document OCR?

The tender record stays public. Those actions live in the private workspace.

Disclaimer: IndexBox Tenders does not issue, announce, or publish this tender. This information is aggregated from publicly available sources and is provided for informational purposes only. IndexBox Tenders is not affiliated with, endorsed by, or acting on behalf of the tender issuer. Users should verify all information directly with the official tender source before making any decisions or taking any action.